Tape Library Setup using the Device Configuration Wizard
The following are the tasks for setting up the tape library when using the Device Configuration Wizard:
2. Install and Configure the Tape Library by Using the DPX Device Configuration Wizard
Following is important information you might need to know before starting:
Launching command line utilities:
From a Linux DPX node, set up the correct environment:
Bring up a terminal window, log in as root, and navigate to the bin directory under the main installation directory.
Enter:
. ./bexenv
Warning! Filesbexenv
andbexads
may be overwritten during upgrades. Users can add custom environment variable settings to thebexenv.conf
andbexads.conf
files using a text editor. Thebexenv
andbexenv.conf
files are contained in the/opt/DPX/bin/
directory and thebexads
andbexads.conf
files are stored in the/opt/DPX/misc
directory. These files will retain user added settings even after an upgrade.Set the DISPLAY environment variable appropriately for your output device, if not already done.
From a Windows DPX node, click Start, click All Programs, then select the product-directory folder, then choose Command Prompt. This sets some important environment variables.
Note that users of Windows 2008 R2 and later must open the Command Prompt window with Run as Administrator, even if logged in as Administrator.
Using the DPX detect utility:
The detect utility displays media changers and tape drives that are accessible from a given device server or controller node. This utility is found in the /bin/JB subdirectory under the main DPX installation directory.
Last updated